Target
- Customers who can use HENNGE Connect are the target.
(For a list of features available for each licensed contract, please check here.)
Purpose
- This explains how to configure the Connected Services for HENNGE Connect.
Notes
- Administrator privileges for Access Control are required to perform this procedure.
- Please refer to the following article for how to access the Administration.
How to access the Access Control Administration - The content of this article is based on the product as of October 2025 and may change without notice thereafter.
- Create the same number of Connected Services as the services you plan to connect.
Procedure
-
Access the [System] - [Edit Connected Service] from the left menu of the Access Control Administration.
-
Click [Add Connected Service].
-
Click [Add New Service] - [Add Service for SSO] and then click [Add Service].
-
Click [Add New Service] - [OIDC].
-
Configure as follows on the settings screen and click [Save].
Item Description Service name Optional service name
This name will be displayed on the user portal.Application URL https://<optional value>※1.<main domain>※2.connect.hennge.io</directory part>※3
Example)https://servicename1.example.com.connect.hennge.io/directoryRedirect URI https://idp.ngrok.com/oauth2/callback Scopes Check openid, profile, email ※1 Enter any string you want to set for this service in <optional value>.
It must be alphanumeric (lowercase) and within 20 characters.
When setting up multiple services, each service must have a unique string.
※2 Enter the domain listed in the header of the Administration for <main domain>.※3 If the URL on the intranet side of the connected service includes a directory part, you need to append the directory part to the end of the Application URL.
Example)If the URL of the on-premises web service is https://connect.hennge.sample.com/directory, enter the Application URL as follows.
https://connect.hennge.sample.com.connect.hennge.io/directory - Reopen the created configuration and obtain the following information.
Please share the following information in the specified HENNGE format.
※ This is necessary for HENNGE to configure HENNGE Connect.- Settings screen
- Application URL
- Metadata screen
- Client ID
- Client secret
- OP Issuer
- Information of the service you want to connect
-
Service URL on the intranet side
-
- Settings screen
- Configure the settings to allow access to the configured service.
You can configure it by access policy group unit or user unit to which the target user belongs.
For details, please refer to the following page.
Access permission settings for SP service